Tablet Disintegration
Tablet Disintegration

Tablet Disintegration

Tablet Disintegration Specification

  • Glass Type
  • Borosilicate
  • Temperature Resistance
  • Up to 100C
  • Shape
  • Rectangular
  • Power Supply
  • AC Mains
  • Features
  • Digital Timer, Temperature Controller, Stainless Steel Basket Assembly
  • Accuracy
  • 1C (temperature), 1 cycle/min (movement)
  • Heating Capacity
  • 500 W
  • Control Type
  • Digital Controls
  • Display Type
  • Digital Display
  • Speed Range
  • 3032 cycles per minute
  • Type
  • Tablet Disintegration Apparatus
  • Dimension (L*W*H)
  • 480 x 300 x 220 mm
  • Equipment Type
  • Laboratory Testing Instrument
  • Equipment Materials
  • Stainless Steel, Borosilicate Glass
  • Power
  • 230 V / 50 Hz, Single Phase
  • Voltage
  • 220240 V
  • Material
  • Stainless Steel
  • Application
  • Tablet Disintegration Testing
  • Capacity (Ltr)
  • 1 L
  • Movement Type
  • Up and down (linear reciprocating)
  • Operating Temperature
  • Room Temperature to 100°C
  • Basket Assembly
  • Two basket assemblies included as per IP/USP standards
  • Stirrer Type
  • Magnetic Stirrer optional
  • Compliance
  • Meets major pharmacopoeial standards (IP/USP/BP)
  • Water Bath Material
  • Corrosion-resistant material
  • Timer Type
  • Digital preset timer
  • Temperature Sensor
  • PT 100 Sensor
  • Timer Range
  • Up to 99 minutes
  • Test Tubes Per Basket
  • 6 per basket
  • Construction
  • Powder coated body with SS components
  • Safety Features
  • Over-temperature protection, auto cut-off
 
 

About Tablet Disintegration



Take advantage of our Last Chance Promotion and seize a stellar discount on the Venerable Tablet Disintegration with Basket Assembly! Designed for precise laboratory testing, this lofty apparatus offers dual basket assemblies compliant with IP/USP standards. Featuring a corrosion-resistant water bath, digital preset timer (up to 99 minutes), and advanced PT 100 temperature sensor, the unit delivers accuracy along with over-temperature safety. Optional magnetic stirrer enhances flexibility. With robust stainless steel and borosilicate glass construction, this trusted equipment's reliability supports rigorous tablet disintegration testing in pharmaceutical applications. Secure your offer today!

Usage & Applications of Tablet Disintegration

Tablet Disintegration Apparatus is vital for pharmaceutical quality control, evaluating how quickly tablets dissolve in specified media. Used in laboratories for research and manufacturing, it supports regulatory compliance testing for tablets and capsules. Application areas include pharma companies, research institutes, and product development labs. Compatible with various disintegration media such as water and simulated gastric or intestinal fluids, this apparatus ensures consistent results across a range of drug formulations.


Certifications and Export, Supply Capability

Tablet Disintegration units meet major pharmacopoeial certifications (IP/USP/BP), ensuring dependable performance. Main export markets include India, Southeast Asia, Africa, and Europe, with a robust supply ability backed by reliable transport services for prompt delivery. Request an estimate for bulk orders or inquire for special offers as a distributor, exporter, manufacturer, supplier or trader. Backed by strong transport partnerships, the apparatus is swiftly shipped to locations worldwide, meeting laboratory needs efficiently.


FAQ's of Tablet Disintegration:


Q: How is the Tablet Disintegration Apparatus used in pharmaceutical testing?

A: The apparatus is commonly used to evaluate the disintegration time of tablets and capsules, ensuring pharmaceutical products meet regulatory standards for quality control. Six test tubes per basket are submerged in a controlled water bath for precise measurement.

Q: What are the major standards that this device complies with?

A: This apparatus meets stringent international pharmacopoeial standards, including IP, USP, and BP, making it suitable for global pharmaceutical testing environments.

Q: When is the optional magnetic stirrer recommended for use?

A: The magnetic stirrer is suggested when the disintegration medium requires constant agitation to maintain uniform dissolution, optimizing test accuracy for specific tablet formulations.

Q: Where can this tablet disintegration equipment be supplied or exported?

A: As a distributor, exporter, manufacturer, supplier, and trader, this laboratory instrument is available for delivery throughout India and exported to international markets in Southeast Asia, Africa, and Europe.

Q: What process controls and safety features are included?

A: It provides digital control for timer and temperature settings, over-temperature protection, auto cut-off, and robust accuracy of 1C and 1 cycle/min, ensuring safe and reliable operation.

Q: What are the benefits of choosing this Tablet Disintegration Apparatus?

A: Benefits include compliance with major standards, durable construction (stainless steel and borosilicate glass), user-friendly digital controls, accurate testing results, and transport services for timely delivery worldwide.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Glassware And Equipments Category

Water Bath Incubator Shaker (Metabolic Shaking Incubator)

Water Bath Incubator Shaker (Metabolic Shaking Incubator)

Type : Other, Metabolic Shaking Incubator

Control Type : Digital PID Controller

Features : Microprocessor controlled temperature and speed, Timer function, Removable tray, Safety thermostat, Overtemperature alarm, Smooth and stable shaking

Power Supply : 230 V AC, 50 Hz

Power : 400W

Material : Stainless Steel

Orbital Shaking Incubator

Orbital Shaking Incubator

Type : Other, Orbital Shaking Incubator

Control Type : Digital Microprocessor Controller

Features : Orbital Shaking Platform, Timer Function, Variable Speed Control, Digital Temperature Control, Transparent Door for Viewing

Power Supply : Single Phase, 50 Hz

Power : 550 W

Material : Stainless Steel and Mild Steel

Tablet Friability Tester

Tablet Friability Tester

Type : Other, Digital Tablet Friability Tester

Control Type : Digital Timer & Speed Control

Features : Auto Stop, Adjustable Speed, Durable Construction

Power Supply : 230 V 10% AC, 50 Hz

Power : 25 W

Material : Stainless Steel

Speed Measurement Trainer Module

Speed Measurement Trainer Module

Type : Other, Trainer Module

Control Type : Digital Control

Features : Robust design, clear panel indicators, reset facility, motor with adjustable speed, test jacks for measurements

Power Supply : Mains operated

Power : 230V AC, 50Hz

Material : High quality metal and acrylic sheet



Back to top